Products
CNG Microcomputer Controller
Back to previous pageCNG Microcomputer Controller
RT-CNG 224 (2flowmeter-2nozzle-4dispaly-2keyboard)
Technical Performances
Working Ambient:
- Adapt temperature: -40℃~ +55℃
- Relative humidity: 30%~90%
- Air pressure: 86~106kPa
Power:
- Voltage: AC220V±20%
- Frequency: (50±1)Hz
Others Characteristics
- Measurement precision: ±0.5%
- Measurement repeatability precision: 50% for Measurement precision
- Flow rate: 1~70litre/min
- Rated working voltage: 20MPa
- Maximum working pressure:25 MPa
- System design pressure:27.5 MPa
- Gas-filling preset range: 0.3-9000 liter
- Density preset range: 0.5000-0.6999
- Rating power: <100W
- Electronic Calibration.
- Stop fueling by integer sale.
- Printer (option)
- Can set the decimal point for the display, so can be used in many country with different currency rate.
The digits number displayed on display screen
- Sale District: 6 digits
- kg District: 6 digits
- Unit Price District: 4 digits
CNG Microcomputer Controller
Setting Dimensions:580×300